测温仪当前位置: 主页 > 产品中心 > 测温仪 >

福禄克Fluke T5-600/62MAX+/1AC II IR Thermometer, Electrica

This kit is designed to help electricians and HVAC technicians solve problems quicker. Test first for overheated electrical devices using an IR thermometer; then use electrical test tools to find out more about the problem.

Fluke T5 Voltage, Continuity and Current Testers.

  • Automatically measures volts ac and volts dc with precise digital resolution.
  • Displays resistance to 1000Ω.
  • Easy and accurate OpenJaw™ current measurement.
  • Continuity beeper.
  • Rugged enough to withstand a 10-foot (3m) drop.
  • 600V model.
  • Auto off mode to conserve battery life.
  • AC current.
  • Display hold.
  • All inputs of the T5-600 are protected to EN61010-1 CAT III 600V. UL, CSA and VDE listed.

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.
  • C115 Deluxe soft carrying case with shoulder strap.

Fluke T5-600 Voltage, Continuity and Current Tester


Specifications
Jaw opening 12.9 mm (0.5 in)
Max wire size 1/0 THHN Cable
Current range ac rms 0 to 100.0 A
Accuracy ac current (50/60 Hz) 3 % ± 3 counts
AC Response Averaging
Voltage range ac 0 to 600 V
Accuracy ac voltage 1.5 % ± 2 counts
Voltage range dc 0 to 600 V
Accuracy dc voltage 1 % ± 1 count
Resistance range 0 to 1000 Ω
Continuity beeper threshold On at <25 Ω, off at >400 Ω
Volts indicator LED threshold Guaranteed on by 30 V ac

Environmental Specifications
Operating Temperature -10 °C to 50 °C
Storage Temperature -30 °C to 60 °C
Humidity (Without Condensation) 0 % to 95 % (5 °C to 30 °C); 0 % to 75 % (30 °C to 40 °C);
0 % to 45 % (40 °C to 50 °C)
Dust/water resistance Yes
Operating Altitude 2000 meters max
Temperature Coefficient 0.1 x (specified accuracy)/°C (<18 °C or >28 °C)

Safety Specifications
Overvoltage category CAT III 600 V ac/dc (EN61010-1)
Agency Approvals UL, CSA, and VDE
Maximum voltage Between any terminal and earth ground

Mechanical and General Specifications
Size 30.5 mm x 51 mm x 203 mm
Weight 300g
Warranty Two-years
Battery Life 200 hour zinc chloride, 400 hour alkaline
Battery type 2 x AA
Low battery indicator Yes
Current sensor opening 12.9 mm
Calibration cycle 1 year
Test leads Type: Heavy duty, flexible leads rated for 1000V use.
Field replaceable leads terminate in male shrouded banana plugs
Probes: One red, one black.
Detachable Slim-Reach™ probe tips
Styles: TP1 Slim Reach™ Test Probes

Safety Specifications
Safety CAT IV 600 V, CAT III, 1000 V
Maximum voltage 1000 V AC rms from earth to ground, in compliance with EN61010

Fluke 62 MAX+ Infrared Thermometer


Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62 MAX+ <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
型号名称描述
Fluke T5-600/62 MAX+Includes:
  • Fluke T5-600
  • Fluke 62 MAX+ IR Thermometer
  • 热门文章
    copyright 2015 乐利中国有限公司 all right