他们都在搜索: 红外热像仪  测温仪
产品中心
联系方式
乐利中国有限公司
地 址:上海市嘉定区杭桂路1112号906室 中波大厦
联系人:丁经理
Q Q:2355898385
传 真:021-38686488
测温仪当前位置: 主页 > 产品中心 > 测温仪 >

福禄克Fluke 116/62 MAX+ Technician’s Combo Kit

For the complete solution to HVAC troubleshooting the extra value-packed HVAC Technician’s Combo Kit, provides the ability to troubleshoot and solve problems more efficiently by providing all the needed accessories an HVAC professional would need in a compact carry case.

Fluke116 Digital Multimeter. Designed by Electricians. Engineered by Fluke.

  • Fluke 116 HVAC Multimeter with Temperature and Microamps.
  • TL175 Hard Point Test Lead Set.
  • TPak ToolPak Magnetic Meter Hanging Strap.
  • Flexible Cuff Pipe Clamp Thermocouple.
  • 80BK Integrated Temperature Probe.
  • 80AK-A Thermocouple Adapter.
  • C115 Deluxe Soft Carrying Case with Shoulder Strap.

Fluke 62 MAX+. Small in size. Big on toughness.

  • Dust and water-resistant: IP54 rated.
  • Rugged: 3-meter (9.8-foot) drop tested.
  • Ergonomically designed: Completely redesigned for a more natural hand fit.
  • Distance to spot: 12:1.
  • Dual lasers: Identifies area to be measured.
  • Large, backlit display: Makes data easier to read, even in dark areas.

Fluke 116 HVAC Multimeter with Temperature and Microamps


Specifications
Maximum voltage between any terminal and earth ground 600 V
Surge protection 6 kV peak per IEC 61010-1 600 V CAT III, Pollution Degree 2
Display 6,000 counts, updates 4 per second
Bar graph 33 segments, updates 32 per second
Operating Temperature -10 °C to + 50 °C
Storage Temperature -40 °C to + 60 °C
Battery type 9 volt Alkaline, NEDA 1604A/ IEC 6LR61
Battery Life 400 hours typical, without backlight

Accuracy Specifications
DC millivolts Range 600.0 mV
Resolution 0.1 mV
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
DC volts Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.00 V / 0.1 V
Accuracy ± ([% of reading] + [counts]): 0.5% + 2
Auto volts Range 600.0 V
Resolution 0.1 V
Accuracy 2.0 % + 3 (dc, 45 Hz to 500 Hz)
4.0 % + 3 (500 Hz to 1 kHz)
AC millivolts1 true-rms Range 600.0 mV
Resolution 0.1 mV
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
AC volts1 true-rms Range/Resolution 6.000 V / 0.001 V
Range/Resolution 60.00 V / 0.01 V
Range/Resolution 600.0 V / 0.1 V
Accuracy 1.0 % + 3 (dc, 45 Hz to 500 Hz)
2.0 % + 3 (500 Hz to 1 kHz)
Continuity Range 600 Ω
Resolution 1 Ω
Accuracy Beeper on < 20 Ω, off > 250 Ω; detects opens or shorts of 500 μs or longer.
Ohms Range/Resolution 600.0 Ω / 0.1 Ω
Range/Resolution 6.000 kΩ / 0.001 kΩ
Range/Resolution 60.00 kΩ / 0.01 kΩ
Range/Resolution 600.0 kΩ / 0.1 kΩ
Range/Resolution 6.000 MΩ / 0.001 MΩ
Accuracy 0.9 % + 1
Range/Resolution 40.00 MΩ / 0.01 MΩ
Accuracy 1.5 % + 2
Diode Test Range/Resolution  2.000 V / 0.001 V
Accuracy  0.9% + 2
Capacitance Range/Resolution 1000 nF / 1 nF
Range/Resolution 10.00 μF / 0.01 μF
Range/Resolution 100.0 μF / 0.1 μF
Range/Resolution 9999 μF / 1 μF
Range/Resolution 100 μF to 1000 μF
Accuracy 1.9% + 2
Range/Resolution > 1000 μF
Accuracy 5% + 20%
LoZ capacitance Range 1 nF to 500 μF
Accuracy 10% + 2 typical
Temperature2 (Type-K thermocouple) Range/Resolution -40 °C to 400 °C / 0.1 °C
Accuracy 1% + 102
Range/Resolution -40 °F to 752 °F / 0.2 °F
Accuracy 1% + 182
AC μamps true-rms (45 Hz to 500 Hz) Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
DC μamps Range/Resolution 600.0 μA / 0.1 μA
Accuracy 1.0% + 2
Hz (V or A input)2 Range/Resolution 99.99 Hz / 0.01 Hz
Range/Resolution 999.99 Hz / 0.1 Hz
Range/Resolution 9.999 Hz / 0.001 Hz
Range/Resolution 50.00 Hz / 0.01 Hz
Accuracy 0.1% + 2

Notes:
1) All ac voltage ranges except Auto-V/LoZ are specified from 1 % to 100 % of range. Auto-V/LoZ is specified from 0.0 V.
2) Temperature uncertainty (accuracy) does not include the error of the thermocouple probe.
3) Frequency is ac coupled, 5 Hz to 50 kHz for ac voltage. Frequency is dc coupled, 45 Hz to 5 kHz for ac current.
4) Temperature Range/Resolution: -40 °F to 752 °F / 0.2 °F


Mechanical & General Specifications
Size 167 x 84 x 46 mm (6.57" x 3.31" x 1.82")
Weight 550 g
Warranty 3 years

Fluke 62 MAX+ Infrared Thermometer


Specifications

Temperature Range

-30 °C to 650 °C (-22 °F to 1202 °F)
Accuracy ±1.0 °C or ±1.0% of reading, whichever is greater
-10 °C to 0 °C: ±2.0
-30 °C to -10 °C: ±3.0
Response Time (95%) Fluke 62+ MAX <300 ms (95% of reading)
Spectral Response 8 to 14 microns
Emissivity 0.10 to 1.00

Optical Resolution

12:1 (calculated at 90% energy)
Display Resolution 0.1 °C (0.2 °F)
Repeatability of Readings ±0.5% of reading or <±0.5 °C (1 °F), whichever is greater
Power AA battery
Battery Life 8 hours with laser and backlight on
Physical Specifications Weight 255 g (8.99 oz)
Size (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches
Operating Temperature 0 °C to 50 °C (32 °F to 122 °F)
Storage Temperature -20 °C to 60 °C (-4 °F to 140 °F), (without battery)
Operating Humidity 10 % to 90 % RH non-condensing at 30 °C (86 °F)
Operating Altitude 2000 meters above mean sea level
Storage Altitude 12,000 meters above mean sea level
IP Rating IP 54 per IEC 60529
Drop Test 3 meters
Vibration and Shock IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 ms
EMC EN 61326-1:2006 EN 61326-2:2006

Standards and Agency Approval

Compliance EN/IEC 61010-1: 2001
Laser Safety FDA and EN 60825-1 Class II
型号名称描述
Fluke 116/62MAX+ KitIncludes:
  • Fluke 116 HVAC Multimeter with Temperature and Microamps
  • Fluke 62 MAX+ Infrared Thermometer
  • 热门文章
    copyright 2015 乐利中国有限公司 all right
    地址:上海市嘉定区杭桂路1112号906室 中波大厦